Target Emulation
SANBlaze target emulation systems for Fibre Channel and SAS provide a virtual, extremely cost-efficient configurable environment for SAN product development, testing and QA.
The systems reduce the need to deploy large farms of physical “scratch” disks or tapes, providing port density, high performance, non-volatile media at a fraction of the cost of physical disks or tapes.
The ability to add latency, have differing read/write sizes, inject a wide variety of errors and save and restore multiple disk configurations provides a flexible and invaluable tool for development, test and QA labs.
Fibre Channel
SANBlaze Storage emulators for Fibre Channel are available with a wide range of configurable Fibre Channel options, which include:
Hardware:
8G:
- Fibre Channel Ports: 2, 4, 8 or 10 Fibre Channel Ports running at 2, 4 or 8 Gbps
- Auto Link Speed and Auto Topology Negotiation
- Three Port Configurations Options:
1 Target Per Port, 512 LUNs per Target (Point to Point Mode)
2-16 Targets Per Port, 30 LUNs per Target
65 Targets Per Port, 4 LUNs per Target
4G:
- Fibre Channel Ports: 2, 4, 12 or 24 Fibre Channel Ports running at 1, 2 or 4 Gbps
- Auto Link Speed and Auto Topology Negotiation
- Three Port Configurations Options:
Target Per Port, 512 LUNs per Target (Point to Point Mode)
16 Targets Per Port, 30 LUNs per Target – for a total of 480 LUNs per port
125 Targets Per Port, 4 LUNs per Target
Software Features:
- Port
- Port Status
- Display, Clear, Define Interval of Port Statistics
- Port Configuration
- Set State, Topology, Speed and number of targets
- Port statistics and Real time performance
- Control Fabric Logins
- Target
- Define LUNS
- Edit Inquiry Stream
- Edit World Wide Node Name
- Edit World Wide Port Name
- Set Hard ALPA
- 3 Target Modes – Up to 125 Targets per port
- Tape Emulation
- LUN
- Variable Size – Up to 4 TByte
- 2 Memory configuration options
- Zero, fixed or variable latency
- Multi-port Mapping - A port-B Port
- Multi-Port Mirroring
- Error Conditions
- Save/Restore Data files to LUN
- Seed a Binary or Data File or Pattern to a LUN
- Possible 500 LUNs per port
- Profiles – Use predefined or build drive or tape profiles
Performance:
- 70,000 + I/O’s per port
- Single port Read or Writes at up to 380 Mbps (depending on FC speed)
- Blazter Mode – Full speed Read/Writes across 24 ports
Error Capabilities:
- Error Injection:
- Single or Multiple Errors per command
- By Number of I/O’s or Time
- Error Conditions on specific LBN or CDB
- State Driven
- Error Conditions:
- Bad CRC
- Busy
- Drop
- QueueFull
- CheckCond
- Read Over/Read Under
- WriteOver/Write Under
- ReadDelay, WriteDelay
- Data Corruption
- LIP
Enhanced Command Features:
- 6/10/12/16 byte CDB
- CDB Histogram – Logging of command frames
- LUN Masking
- Persistent Reservations
- Reserve and Release
- User Definable Mode, Diagnostic and Custom Inquiry Pages
- Selectable Queue depth
- Variable Block Size (512 or 520 Byte)
| |
|
|
Data sheets, app notes and white papers
|
 |
|